AT Commands for Telecom IOT Application
No | Command | Description |
C1301 | AT+SIMLCREATE | Create configuration |
C1302 | AT+SIMLMODE | Connection mode |
C1303 | AT+SIMLOPEN | Connect to Telecom IOT |
C1304 | AT+SIMLSEND | Send data to Telecom IOT |
C1305 | AT+SIMLCLOSE | Disconnect to Telecom IOT |
C1301 AT+SIMLCREATE Create Configuration
T) AT+SIMLCREATE=? |
+SIMLCREATE: <config>
OK |
Parameters See Write Command |
|
W) AT+SIMLCREATE=<config> | OK |
Parameters <config> Config in hex format |
|
Parameter Saving Mode | NO_SAVE |
C1302 AT+SIMLMODE Connection Mode
T) AT+SIMLMODE=? |
+SIMLMODE: <mode>
OK |
Parameters See Write Command |
|
W) AT+SIMLMODE=<mode> | OK |
Parameters <mode> Connection mode 1 Other 2 China Telecom IOT |
|
Parameter Saving Mode | NO_SAVE |
C1303 AT+SIMLOPEN Connect To Telecom IOT
T) AT+SIMLOPEN=? |
+SIMLOPEN: <lifetime>
OK |
Parameters See Write Command |
|
W) AT+SIMLOPEN=<lifetime> | OK |
Parameters <lifetime> Reserved |
|
Parameter Saving Mode | NO_SAVE |
C1304 AT+SIMLSEND Send Data To Telecom IOT
T) AT+SIMLSEND=? |
+SIMLSEND: <data>,<flag>
OK |
Parameters See Write Command |
|
W) AT+SIMLSEND=<data>,<flag> | OK |
Parameters <data> String in hex format <flag> 0 Input over 1 Input not over |
|
Parameter Saving Mode | NO_SAVE |
C1305 AT+SIMLCLOSE Disconnect To Telecom IOT
E) AT+SIMLCLOSE | OK |