AT Commands for  Telecom IOT Application

 

No Command Description
C1301 AT+SIMLCREATE Create configuration
C1302 AT+SIMLMODE Connection mode
C1303 AT+SIMLOPEN Connect to Telecom IOT
C1304 AT+SIMLSEND Send data to Telecom IOT
C1305 AT+SIMLCLOSE Disconnect to Telecom IOT

 

 

 

 

C1301     AT+SIMLCREATE      Create Configuration

 

T) AT+SIMLCREATE=?

+SIMLCREATE: <config>

 

OK

Parameters

See Write Command

W) AT+SIMLCREATE=<config> OK

Parameters

<config>     Config in hex format

Parameter Saving Mode NO_SAVE

 

 

 

 

C1302     AT+SIMLMODE      Connection Mode

 

T) AT+SIMLMODE=?

+SIMLMODE: <mode>

 

OK

Parameters

See Write Command

W) AT+SIMLMODE=<mode> OK

Parameters

<mode>     Connection mode

1     Other

2     China Telecom IOT

Parameter Saving Mode NO_SAVE

 

 

 

 

C1303     AT+SIMLOPEN      Connect To Telecom IOT

 

T) AT+SIMLOPEN=?

+SIMLOPEN: <lifetime>

 

OK

Parameters

See Write Command

W) AT+SIMLOPEN=<lifetime> OK

Parameters

<lifetime>     Reserved

Parameter Saving Mode NO_SAVE

 

 

 

 

C1304     AT+SIMLSEND      Send Data To Telecom IOT

 

T) AT+SIMLSEND=?

+SIMLSEND: <data>,<flag>

 

OK

Parameters

See Write Command

W) AT+SIMLSEND=<data>,<flag> OK

Parameters

<data>     String in hex format

<flag>

0     Input over

1     Input not over

Parameter Saving Mode NO_SAVE

 

 

 

 

C1305     AT+SIMLCLOSE      Disconnect To Telecom IOT

 

E) AT+SIMLCLOSE OK

 

 

 

 